is engineered for the typical of steel mills. Key installation guidelines from the manual include:
Requires 24 VDC ± 20% with a consumption of roughly 7.2W. id6100 danieli manual hot
Can be enabled to automatically adapt the scan period to the radiation intensity. is engineered for the typical of steel mills
DANIELI AUTOMATION ID6100 INSTRUCTION MANUAL Pdf Download | ManualsLib. ManualsLib id6100 danieli manual hot
details its operation as a loop position detector, helping to maintain material tension between two rolling stands by providing real-time feedback to automation controls. According to the official instruction manual features several critical performance metrics: Detection Spectrum: 830 to 1000 nm. Object Temperature Range: 700 to 1200°C (1300 to 2200°F).
Users must ensure that cooling does not become excessive, as condensation on the glass window can block IR detection.